With the word repetitive in its name, it’s no surprise that pipetting— the most repetitive part of your job— causes Repetitive stress injury. Ignoring repetitive strain can lead to permanent nerve damage, like carpal tunnel syndrome, De Quervain syndrome and repetitive strain injury (RSI), and end a bench science career. With unmatched precision and accuracy, Accumax LF Pipettes offers a wide range of variants, ensuring high flexibility for diverse applications. Remarkably lightweight, it alleviates hand and arm strain, prioritizing user comfort.
The high cost of hand fatigue due to high force and repetition lead to:
LF or Low Force, has emerged as a highly sought-after solution for improving pipetting ergonomics in the lab. Its simplicity and elegance address the challenges of achieving a flawless tip seal and effortlessly ejecting tips with minimal physical force Accumax LF pipette tips available in volumes from 20uL-1000uL meet the highest cleanliness and purity standards.
Know more about Accumax LF Tips that are the perfect fit to Accumax LF pipettes.
Cat. No | Volume Range [μl] | Increments [μl] | Test Volume [μl] | Inaccuracy (±) % | Imprecision (±) % |
---|---|---|---|---|---|
ALFV-2.5 | 0.1-2.5 | 0.002 | 0.25 | -0.6 | 2.1 |
1.25 | 0.3 | 1.0 | |||
2.5 | -0.3 | 0.7 | |||
ALFV-10 | 0.5-10 | 0.02 | 1 | 0.0 | 1.4 |
5 | 0.5 | 0.5 | |||
10 | 0.1 | 0.3 | |||
ALFV-20 | 2-20 | 0.02 | 2 | -0.5 | 0.7 |
10 | 0.0 | 0.2 | |||
20 | 0.2 | 0.2 | |||
ALFV-50 | 5-50 | 0.1 | 5 | -0.1 | -0.1 |
25 | -0.2 | 0.1 | |||
50 | 0.0 | 0.0 | |||
ALFV-100 | 10-100 | 0.1 | 10 | -0.1 | 0.5 |
50 | -0.2 | 0.2 | |||
100 | 0.3 | 0.1 | |||
ALFV-200 | 20-200 | 0.2 | 20 | -0.3 | 0.4 |
100 | 0.1 | 0.2 | |||
200 | 0.3 | 0.1 | |||
ALFV-1000 | 100-1000 | 1 | 100 | -0.2 | 0.4 |
500 | 0.1 | 0.2 | |||
1000 | 0.2 | 0.1 |
Cat. No | Volume Range [μl] | Inaccuracy (±) % | Imprecision (±) % |
---|---|---|---|
ALFF-2.5 | 2.5 | -0.32 | 0.69 |
ALFF-5 | 5 | 0.53 | 0.53 |
ALFF-10 | 10 | 0.02 | 0.20 |
ALFF-20 | 20 | 0.15 | 0.15 |
ALFF-25 | 25 | -0.17 | 0.08 |
ALFF-50 | 50 | 0.34 | 0.03 |
ALFF-100 | 100 | 0.31 | 0.07 |
ALFF-200 | 200 | 0.27 | 0.08 |
ALFF-250 | 250 | 0.4 | 0.4 |
ALFF-500 | 500 | 0.13 | 0.18 |
ALFF-1000 | 1000 | 0.22 | 0.10 |
Cat. No. | Volume Range [ µl ] |
Increment [ µl ] |
---|---|---|
ALFM8-010 | 0.5 – 10 µl | 0.02 |
ALFM8-020 | 2 – 20 µl | 0.02 |
ALFM8-050 | 5- 50 µl | 0.1 |
ALFM8-100 | 10 – 100 µl | 0.1 |
ALFM8-200 | 20 – 200 µl | 0.2 |
ALFM8-300 | 30 – 300 µl | 0.2 |
ALFM8-1200 | 120-1200 µl | 1.0 |
Cat. No. | Volume Range [ µl ] |
Increment [ µl ] |
---|---|---|
ALFM12-010 | 0.5 – 10 µl | 0.02 |
ALFM12-020 | 2 – 20 µl | 0.02 |
ALFM12-050 | 5- 50 µl | 0.1 |
ALFM12-100 | 10 – 100 µl | 0.1 |
ALFM12-200 | 20 – 200 µl | 0.2 |
ALFM12-300 | 30 – 300 µl | 0.2 |
ALFM12-1200 | 120 – 1200 µl | 1.0 |
LF or Low Force, has emerged as a highly sought-after solution for improving pipetting ergonomics in the lab. Its simplicity and elegance address the challenges of achieving a flawless tip seal and effortlessly ejecting tips with minimal physical force Accumax LF pipette tips available in volumes from 20uL-1000uL meet the highest cleanliness and purity standards.
Know more about Accumax LF Tips that are the perfect fit to Accumax LF pipettes.
Cat. No | Volume Range [μl] | Increments [μl] | Test Volume [μl] | Inaccuracy (±) % | Imprecision (±) % |
---|---|---|---|---|---|
ALFV-2.5 | 0.1-2.5 | 0.002 | 0.25 | -0.6 | 2.1 |
1.25 | 0.3 | 1.0 | |||
2.5 | -0.3 | 0.7 | |||
ALFV-10 | 0.5-10 | 0.02 | 1 | 0.0 | 1.4 |
5 | 0.5 | 0.5 | |||
10 | 0.1 | 0.3 | |||
ALFV-20 | 2-20 | 0.02 | 2 | -0.5 | 0.7 |
10 | 0.0 | 0.2 | |||
20 | 0.2 | 0.2 | |||
ALFV-50 | 5-50 | 0.1 | 5 | -0.1 | -0.1 |
25 | -0.2 | 0.1 | |||
50 | 0.0 | 0.0 | |||
ALFV-100 | 10-100 | 0.1 | 10 | -0.1 | 0.5 |
50 | -0.2 | 0.2 | |||
100 | 0.3 | 0.1 | |||
ALFV-200 | 20-200 | 0.2 | 20 | -0.3 | 0.4 |
100 | 0.1 | 0.2 | |||
200 | 0.3 | 0.1 | |||
ALFV-1000 | 100-1000 | 1 | 100 | -0.2 | 0.4 |
500 | 0.1 | 0.2 | |||
1000 | 0.2 | 0.1 |
Cat. No | Volume Range [μl] | Inaccuracy (±) % | Imprecision (±) % |
---|---|---|---|
ALFF-2.5 | 2.5 | -0.32 | 0.69 |
ALFF-5 | 5 | 0.53 | 0.53 |
ALFF-10 | 10 | 0.02 | 0.20 |
ALFF-20 | 20 | 0.15 | 0.15 |
ALFF-25 | 25 | -0.17 | 0.08 |
ALFF-50 | 50 | 0.34 | 0.03 |
ALFF-100 | 100 | 0.31 | 0.07 |
ALFF-200 | 200 | 0.27 | 0.08 |
ALFF-250 | 250 | 0.4 | 0.4 |
ALFF-500 | 500 | 0.13 | 0.18 |
ALFF-1000 | 1000 | 0.22 | 0.10 |
Cat. No. | Volume Range [ µl ] |
Increment [ µl ] |
---|---|---|
ALFM8-010 | 0.5 – 10 µl | 0.02 |
ALFM8-020 | 2 – 20 µl | 0.02 |
ALFM8-050 | 5- 50 µl | 0.1 |
ALFM8-100 | 10 – 100 µl | 0.1 |
ALFM8-200 | 20 – 200 µl | 0.2 |
ALFM8-300 | 30 – 300 µl | 0.2 |
ALFM8-1200 | 120-1200 µl | 1.0 |
Cat. No. | Volume Range [ µl ] |
Increment [ µl ] |
---|---|---|
ALFM12-010 | 0.5 – 10 µl | 0.02 |
ALFM12-020 | 2 – 20 µl | 0.02 |
ALFM12-050 | 5- 50 µl | 0.1 |
ALFM12-100 | 10 – 100 µl | 0.1 |
ALFM12-200 | 20 – 200 µl | 0.2 |
ALFM12-300 | 30 – 300 µl | 0.2 |
ALFM12-1200 | 120 – 1200 µl | 1.0 |
Still have questions? Schedule a live demonstration.